What Is ESR? Measuring Electrolytic Capacitor ESR

ESR (equivalent series resistance) represents all the losses inside a capacitor as a single series resistance. As an electrolytic capacitor ages, its capacitance often stays close to the rated value while its ESR rises; this is why a multimeter’s capacitance range usually fails to catch a bad capacitor. The most practical way to find the faulty part is to measure ESR at about 100 kHz and compare the reading with the 100 kHz impedance limit in that capacitor’s datasheet, if one is given, or otherwise with a healthy capacitor doing the same job.
In this article we explain where ESR comes from, how to derive a “good” limit from the datasheet, how to measure it with an ESR meter and an oscilloscope, and what to check when choosing a replacement part, using two Rubycon capacitors as examples: the low-impedance 50ZL330MEFCT810X23 (50 V, 330 µF) and the general-purpose 16PX680MEFC8X11.5 (16 V, 680 µF).
What is ESR and where does it come from?
A real aluminum electrolytic capacitor behaves like three elements in series: the ideal capacitance (C), the equivalent series resistance (ESR) and the equivalent series inductance (ESL) contributed by the leads and the winding. At high frequencies most of the ESR comes from the resistance of the liquid electrolyte, and the rest from the aluminum foil, tab connections and leads. As the electrolyte evaporates and dries out over time, ESR rises; this is the main aging mechanism of electrolytic capacitors.

The total impedance of the capacitor is given by Z = √(ESR² + (XL − XC)²). Two practical conclusions follow:
- Z is always greater than or equal to ESR. The maximum impedance value given in the datasheet is also an upper limit for ESR at the same frequency.
- At high frequencies, capacitive reactance drops almost to zero. The reactance of a 680 µF capacitor at 100 kHz is XC = 1 / (2π · 100,000 · 0.00068) ≈ 0.0023 Ω. At this frequency, the impedance measured on a high-capacitance electrolytic is mostly ESR; for small values such as 1–10 µF, however, the reactance is still on the order of ohms (about 1.6 Ω for 1 µF). This is why ESR meters operate at around 100 kHz.
The relationship between tan δ and ESR
Many general-purpose electrolytic capacitor datasheets do not list ESR; instead they give the loss tangent (tan δ, dissipation factor) measured at 120 Hz. The two are converted with the following formula:
ESR = tan δ / (2π · f · C)
For the 16PX680, tan δ in the 16 V class is 0.20 max. At 120 Hz: ESR ≤ 0.20 / (2π · 120 · 0.00068) ≈ 0.39 Ω. For the 50ZL330, tan δ in the 50 V class is 0.10 max: ESR ≤ 0.10 / (2π · 120 · 0.00033) ≈ 0.40 Ω. The two capacitors look almost identical at 120 Hz; the difference between them shows up at high frequencies. These 120 Hz values cannot be compared directly with the reading of an ESR meter operating at 100 kHz.
Deriving good/bad limits from the datasheet
There is no single answer to the question “what should the ESR of a good capacitor be”; the value varies with capacitance, voltage class, case size and series. The correct reference is the datasheet of the part you are replacing or measuring. The values below are taken from Rubycon’s ZL and PX series catalogs.
| Parameter | 50ZL330MEFCT810X23 | 16PX680MEFC8X11.5 |
|---|---|---|
| Series type | 105 °C, high ripple current, low impedance | 105 °C, standard (general purpose) |
| Rated voltage / capacitance | 50 V / 330 µF (±20%) | 16 V / 680 µF (±20%) |
| Case (diameter × length) | 10 × 23 mm | 8 × 11.5 mm |
| tan δ (max, 20 °C, 120 Hz) | 0.10 | 0.20 |
| ESR calculated from tan δ (max, 120 Hz) | ≈ 0.40 Ω | ≈ 0.39 Ω |
| Impedance (max, 100 kHz, 20 °C) | 0.028 Ω | Not given in datasheet |
| Impedance (max, 100 kHz, −10 °C) | 0.085 Ω | Not given in datasheet |
| Rated ripple current | 1870 mA rms (105 °C, 100 kHz) | 480 mA rms (105 °C, 120 Hz); ×1.20 at 10 kHz and above |
| Lifetime (105 °C, at rated voltage and ripple current) | 4000 hours | 1000 hours |
| Leakage current (rated voltage, after 2 minutes) | ≤ 0.01·C·V = 165 µA | ≤ 0.01·C·V ≈ 109 µA |
| Operating temperature | −40 … +105 °C | −55 … +105 °C |
Keep three points in mind when reading the table:
- The acceptance limit after the endurance test is, in practice, used as the end-of-life criterion. In both series, a part operated at 105 °C for the rated time must keep its capacitance within ±25% of the initial value, and its tan δ must not exceed 200% of the catalog value. If capacitance has not changed much, tan δ doubling means the 120 Hz ESR roughly doubles as well. So for the 16PX680, about 0.78 Ω at 120 Hz is the upper limit the manufacturer still accepts at the end of the test. If capacitance has dropped by the permitted 25%, the same tan δ corresponds to about 2.7 times the ESR.
- ESR increases in the cold. The 100 kHz impedance of the 50ZL330 can rise to 0.085 Ω at −10 °C, roughly three times its 20 °C value. Keep this behavior in mind with equipment that fails to start on the first power-up in winter but recovers once it warms up, and take your measurements at room temperature.
- For a series without a 100 kHz impedance in the datasheet, there is no direct number to compare an ESR meter reading against. In that case, comparing with a healthy capacitor of the same value and series in the same circuit, or measuring tan δ at 120 Hz with an LCR meter, is a more reliable approach.
Rubycon marks the ZL series as discontinued in its catalog. The 50ZL330 is suitable as a repair replacement for a low-impedance capacitor of the same value; for a new design, however, you should look at the manufacturer’s current low-impedance series.
Why does ESR lead to failure?
Ripple current generates heat in the ESR: P = I²rms · ESR. The rated 100 kHz ripple current of the 50ZL330 is 1.87 A rms. If we take ESR as the 100 kHz impedance limit of 0.028 Ω, the loss is at most 1.87² · 0.028 ≈ 0.098 W. If ESR increases tenfold to 0.28 Ω at the same current, the heat also increases tenfold to about 0.98 W. The electrolyte of a hot capacitor dries out faster, ESR rises further, and the part enters a self-accelerating degradation. A bulging top vent and electrolyte leaking from the base are the final stages of this process.
On the circuit side, high ESR shows up with the following symptoms:
- A switch-mode power supply (SMPS) that does not start at all, clicks on and off, or whose output voltage drops under load.
- Increased output ripple; hum in audio equipment, flicker or lines on displays.
- Output-capacitor-related instability in DC-DC converters. We discuss the effect of ESR on the regulation loop separately in our MC34063 step-down calculation article.
How is ESR measured?
1. With an ESR meter
ESR meters apply a small-amplitude AC signal at around 100 kHz to the capacitor and calculate the resistance from the voltage drop. Because the applied amplitude is kept low, the diode and transistor junctions in the circuit usually do not turn on; as a result, the measurement can often be made without desoldering the capacitor. The 150 kHz analog ESR meter project shared on 320volt is a good starting example for anyone who wants to build this operating principle themselves (link in the References section).
There are two limitations when measuring in-circuit: other capacitors connected in parallel make the reading lower than it really is, and a shorted capacitor also looks “very good” (close to zero) on an ESR meter. If you get a suspicious reading, desolder the part, measure it again, and check for a short with a multimeter.
2. With an oscilloscope and a signal generator
If you do not have an ESR meter, the same measurement can be made with a simple voltage divider. Feed the generator output through a known series resistor (R) to the capacitor, with the capacitor’s negative terminal connected to ground. Use one oscilloscope channel to measure the voltage on the generator side of the resistor (Vg) and the other channel to measure the voltage across the capacitor (Vc).

Because the capacitor behaves almost like a pure resistance at 100 kHz, the voltage divider formula applies:
ESR ≈ R · Vc / (Vg − Vc)
Worked example: R = 10 Ω, Vg = 1.00 V peak-to-peak, and 40 mV peak-to-peak is read across the capacitor. ESR ≈ 10 · 0.04 / 0.96 ≈ 0.42 Ω. If this measurement had been made on a 50ZL330, the result would be about 15 times the 0.028 Ω 100 kHz impedance limit in the datasheet, and the part would need to be replaced.
This method has two limitations. First, it measures total impedance, not ESR: the ESL of the leads and the remaining capacitive reactance are added to the result. On a worn part reading a few hundred milliohms this effect is negligible, but on a healthy low-impedance capacitor an extra few milliohms is significant next to a value like 0.028 Ω. Second, in the same setup only about 2.8 mV peak-to-peak appears across a healthy 50ZL330 capacitor, which is close to the noise floor of most oscilloscopes. So this setup is suitable for identifying faulty parts at 0.3 Ω and above; verifying a limit in the milliohm range requires a smaller R or a higher amplitude. Use short, direct connections and attach the probe ground lead right at the base of the capacitor lead.
3. With an LCR meter
If you have an LCR meter, measure capacitance and dissipation factor (D, i.e. tan δ) at 120 Hz. Since this value is measured under the same conditions as the tan δ row in the datasheet, it can be compared directly. If the measured D exceeds twice the catalog value, the capacitor has also exceeded the manufacturer’s end-of-life criterion.
Finding the faulty capacitor step by step
- Unplug the device and discharge the capacitors. The high-voltage capacitors on the primary side of an SMPS can hold a dangerous voltage even after the device is unplugged. Discharge them with a suitably rated resistor and confirm with a multimeter that the voltage has dropped to zero.
- Inspect visually. Look for a bulging top vent, brown residue at the base, and shrinkage or discoloration of the plastic (PET) sleeve. Start with the capacitors located near heat sources (heat sinks, power resistors).
- Measure ESR in-circuit. Compare each capacitor’s reading with a neighbor of the same value or the same function. Mark any that are noticeably higher.
- Desolder the suspect and measure again. On the removed part, check ESR, capacitance and shorts together. If possible, compare the reading with the 100 kHz impedance value in the datasheet.
- Choose the replacement part (next section) and install it, paying attention to polarity.
- Test the circuit. Check the output voltage under load and, if possible, the ripple with an oscilloscope.
If you also suspect a transistor or MOSFET failure on the same board, see our MOSFET testing and transistor testing guides. For the fast diodes that are often replaced together with capacitors in SMPS units, our 1N4007, UF4007 and 1N5819 comparison article will guide you.
Choosing a replacement capacitor
- Keep the same capacitance and the same or a higher voltage. Do not go down in voltage class.
- Use a 105 °C temperature rating. An 85 °C part has a shorter life in power supplies.
- Ripple current and impedance should be no worse than the original. Installing a general-purpose part in place of a low-impedance capacitor is a common mistake. Comparing at the same 16 V 680 µF value: the rated ripple current of the 16PX680 in the PX series is 480 mA rms at 120 Hz and 576 mA rms at 10 kHz and above; in the ZL catalog, the same value is listed at 1250 mA rms in an 8 × 20 mm case and 1430 mA rms in a 10 × 16 mm case (100 kHz). If a standard-series part replaces a low-impedance capacitor carrying high-frequency ripple current at an SMPS output, it heats up quickly and the same failure soon recurs.
- Check the size and lead spacing. The 50ZL330 has a 5.0 mm lead spacing in a 10 × 23 mm case, and the 16PX680 has a 3.5 mm lead spacing in an 8 × 11.5 mm case. Check that it fits the board’s holes and the clearance above the board.
- Consider replacing the capacitors in the same group together. Parts that have run for the same time at the same temperature age in a similar way.
For other capacitance and voltage values, browse the aluminum electrolytic capacitors category, where you can filter by capacitance, voltage, lifetime and ripple current.
Common mistakes
- Measuring only capacitance and calling the part “good”. A capacitor whose capacitance matches its label may have an ESR that has risen several times over.
- Comparing ESR calculated from 120 Hz tan δ with a 100 kHz ESR meter reading. The two values are defined at different frequencies; for the 50ZL330, the limit calculated from 120 Hz is 0.40 Ω, while the 100 kHz impedance limit is 0.028 Ω.
- Trusting a low in-circuit reading. Parallel capacitors and a shorted part make ESR look better than it really is.
- Measuring a cold part or a hot board. ESR changes significantly with temperature; take measurements at room temperature.
- Using long probe leads. In milliohm-range measurements, lead and contact resistance add to the result. Use the ESR meter’s zeroing (short-circuit calibration) feature if it has one.
Frequently asked questions
What should the ESR of a good electrolytic capacitor be, in ohms?
There is no single value. If the datasheet of the part you are measuring gives a 100 kHz impedance value, a good part measured at room temperature should read close to or below that value; for example, 0.028 Ω max at 20 °C for the 50ZL330. Probe connections and lead inductance can raise the reading slightly. If only tan δ is given, calculate the 120 Hz ESR with ESR = tan δ / (2π · f · C); the manufacturer’s end-of-life criterion is tan δ reaching twice its rated value.
Can ESR be measured without desoldering the capacitor?
Usually yes. The low-amplitude signal of an ESR meter does not turn on semiconductor junctions. However, capacitors connected in parallel lower the reading and a shorted part also looks good; desolder the suspect part to confirm.
Can ESR be measured with a multimeter?
The resistance range of a standard multimeter measures with DC and does not show the capacitor’s ESR; the capacitance range measures only capacitance. ESR requires an ESR meter, an LCR meter, or an oscilloscope and a signal generator.
Can a standard capacitor replace a low-ESR capacitor?
This is not recommended. Low-impedance series are chosen to carry high-frequency ripple current. A standard part runs hotter at the same current, its life is shortened, and output ripple increases. When replacing, choose a part with ripple current and impedance equal to or better than the original.
Why can a capacitor with the correct capacitance still be faulty?
As the electrolyte dries out, ESR rises first, and the drop in capacitance comes later. A part with high ESR may keep its capacitance, but it cannot filter the ripple current and it heats up.
Conclusion
In electrolytic capacitor failures, the decisive measurement is ESR, and that measurement only becomes meaningful when read together with the datasheet. Measure at 100 kHz and compare the result with the part’s 100 kHz impedance limit or, if there is none, with a healthy capacitor doing the same job; keep the 120 Hz tan δ values for LCR measurements. When replacing, make sure voltage, temperature rating, ripple current and impedance are no worse than the original.
References
Products in this article
-
$0.5550ZL330MEFCT810X23
Rubycon · RAF2-3CAP ALUM 330UF 20% 50V RADIALRoHS compliant87 In Stock -
$0.2516PX680MEFC8X11.5
Rubycon · EE02109-2CAP ALUM 680UF 20% 16V THRoHS compliant48 In Stock
More from Arıza Tespiti ve Onarım
- Arıza Tespiti ve OnarımBeginner
How to Test a Transistor: NPN and PNP Check with a Multimeter
How to test a transistor with a multimeter: six diode-mode checks for NPN and PNP, expected values, finding the pins, and BC547, BC556B and…
- Arıza Tespiti ve OnarımBeginner
How to Test a Triac: Multimeter and Lamp Test
How do you test a triac with a multimeter, and which reading indicates a short? Step-by-step test of the BT137 triac and BT151 thyristor…
- Arıza Tespiti ve OnarımIntermediate
How to Test a MOSFET: Step by Step with a Multimeter
How to test a MOSFET with a multimeter: gate discharge, body diode, conduction check and the P-channel difference, step by step with IRF630A, BUZ271…