How to Test a Triac: Multimeter and Lamp Test

Arıza Tespiti ve Onarım Beginner 10 min read Published:
Triyak sembolü ve Triyak Nasıl Ölçülür başlığı

A triac is tested in two stages after it has been removed from the board. First, use a multimeter to check for a short between MT1 and MT2: a good triac reads open circuit in both directions. Then try triggering it with a 12 V supply, an incandescent lamp and a resistor: a good triac lights the lamp when the button is pressed and keeps it lit after the button is released. A multimeter on its own only catches a short and a broken gate connection; the lamp test shows whether the triac actually triggers.

This article walks through both methods step by step. As examples we use the 8 A BT137-600E triac and the 12 A BT151-650R thyristor; all the numbers come from these parts’ datasheets. All tests are done at 12 V DC, so you never need to touch mains voltage.

What is a triac, and how does it differ from a thyristor?

A triac is a three-terminal semiconductor that turns on with a small current applied to its gate and can switch both half-cycles of alternating current. Its terminals are called MT1, MT2 and G (gate). In dimmers, heater and motor control, and the boards of appliances such as washing machines, the element that switches the load on and off is usually a triac.

A thyristor (SCR), on the other hand, passes current in one direction only, from anode to cathode. Its terminals are called anode (A), cathode (K) and gate (G). What the two devices have in common is latching: once triggered, they stay on even if the gate current is removed, until the current through them falls below a certain value. The test method is based on this behavior.

Pin connections: BT137 and BT151

Both parts come in the TO-220AB package, and with the marked face toward you and the leads pointing down, the pins are numbered 1, 2, 3 from left to right. According to the datasheets, the pinout is as follows:

Pin BT137-600E (triac) BT151-650R (thyristor)
1 MT1 Cathode (K)
2 MT2 Anode (A)
3 Gate (G) Gate (G)
Metal tab Connected to MT2 Connected to anode
Pin connections of the BT137-600E triac and BT151-650R thyristor in a TO-220 package: 1 MT1 or cathode, 2 MT2 or anode, 3 gate
BT137-600E and BT151-650R pinout. On both parts the metal tab is connected to pin 2.

The fact that the metal tab is connected to pin 2 matters in repair work: while the device is running, the tab of a triac screwed to a heatsink is at mains potential unless an insulator has been fitted between them. If you are going to measure a different triac or thyristor, always check its pinout in that part’s datasheet.

Four values you need to know for the test

Four lines in the datasheet determine how a triac will behave during the test. The values in the table are the maximum limits given for 25 °C.

Parameter What does it mean? BT137-600E BT151-650R
IGT (gate trigger current) The current that must be applied to the gate to turn the part on 10 mA max. (25 mA in the T2− G+ quadrant) 15 mA max.
VGT (gate trigger voltage) The voltage seen at the gate terminal at the moment of triggering 1.5 V max. 1.5 V max.
IL (latching current) The current the load must draw at that moment for conduction to continue when the gate current is removed 25 mA max. (35 mA in two quadrants) 40 mA max.
IH (holding current) The minimum current needed to keep a conducting part from turning off 20 mA max. 20 mA max.

The test circuit is designed according to this table. The gate current in the circuit must be greater than the IGT maximum, and the load current must be greater than the IL maximum. Otherwise a good part may not trigger and may be mistaken for a faulty one.

How do you test a triac with a multimeter?

Before measuring, unplug the device, make sure the large capacitors on the board have discharged, and remove the triac from the board. Measuring on the board is misleading, because the snubber circuit connected in parallel with the triac and the load itself change the reading.

  1. Between MT1 and MT2: Set the multimeter to resistance or diode mode, hold the probes on pins 1 and 2, then swap the probes. A good triac reads open circuit (OL) in both directions. A value close to zero or a continuity beep means the triac is shorted. A load that never switches off, for example a heater or motor that runs continuously, is the typical symptom of this fault.
  2. Between MT2 and gate: Pins 2 and 3 should also read open circuit in both directions.
  3. Between gate and MT1: Between pins 3 and 1 the multimeter shows a value; on triacs this reading is usually obtained in both directions. If it reads open circuit in both directions, the gate connection is broken; a value close to zero or a continuity beep indicates a short between the gate and MT1. The datasheet gives no figure for this measurement, and the value read varies from part to part and from multimeter to multimeter. So do not look for a specific value; just rule out the open-circuit and short-circuit conditions.

For a thyristor, the same sequence applies to anode-cathode (2 and 1), anode-gate (2 and 3) and gate-cathode (3 and 1). Anode to cathode must be open circuit in both directions. Between gate and cathode there is a reading in at least one direction; open circuit in both directions means the gate connection is broken.

Why isn’t a multimeter enough on its own?

The multimeter test reliably catches a shorted triac, but it does not guarantee that the triac can trigger and stay on. The test current that multimeters supply in diode and resistance modes is small. The BT137-600E may need up to 10 mA to trigger and up to 20 mA to stay on. For this reason, “triggering with a multimeter” by briefly touching the gate to MT2 works with some triacs and not with others; a failed attempt does not prove the part is faulty. A definite verdict requires testing the part with a real load current.

Triac test with a lamp circuit

Because the lamp test operates the triac at a current above the trigger and latching currents in the datasheet, it shows both triggering and latching. You will need:

  • 12 V DC supply: a battery or a regulated adapter that can deliver at least 1 A
  • 12 V 5 W incandescent lamp (do not use an LED bulb)
  • 330 Ω resistor (0.5 W)
  • Momentary push button
Schematic of a triac test circuit made of a 12 V supply, a 12 V 5 W lamp, a 330 ohm resistor and a push button; the lamp connects to the MT2 terminal, and the gate connects to the supply through the resistor and button
Lamp test circuit for triacs and thyristors. For a thyristor, connect the anode in place of MT2 and the cathode in place of MT1.

The wiring is as follows: the lamp goes between one terminal of the supply and the triac’s MT2 pin (2). The MT1 pin (1) goes to the other terminal of the supply. The gate pin (3) connects through the 330 Ω resistor and the button to the supply-side terminal of the lamp.

Triac test steps

  1. Build the circuit with the positive terminal of the supply on the lamp side and apply power. Without pressing the button, the lamp should stay off.
  2. Press the button briefly. The lamp should light.
  3. Release the button. The lamp should stay lit; the triac has latched.
  4. Disconnect and reconnect the supply. The lamp should start off.
  5. Swap the positive and negative terminals of the supply and repeat steps 1-4. Because a triac can conduct in both directions, the result should be the same.

The first setup tests the triac with MT2 positive and gate positive (the T2+ G+ quadrant), and the reverse-polarity setup tests it with MT2 negative and gate negative (the T2− G− quadrant). This way both conduction directions of the triac are tested.

Thyristor (SCR) test

For the BT151-650R, connect the anode (2) to the lamp and the cathode (1) to the negative terminal of the supply, and follow the first four steps above. In reverse polarity, only check that the lamp stays off and do not press the button: the BT151 datasheet allows at most 5 V to be applied to the gate in the reverse direction, and 12 V connected in reverse exceeds this limit. If the lamp lights in reverse polarity, the thyristor is shorted.

Interpreting the results

Observation Meaning
The lamp lights without pressing the button MT1-MT2 (or anode-cathode) is shorted; the part is faulty
The lamp does not light when the button is pressed The part does not trigger; the gate may be open. First check that the lamp and the connections are good
The lamp lights only while the button is held The part does not latch; first check that the lamp is incandescent and 5 W, and that the supply delivers clean DC
The triac works in one polarity but not in the other One direction of the triac is faulty; the part should be replaced
Press: lights; release: stays lit; resets when the supply is cut The part passed this test

This test shows that the part triggers and latches; it does not test the rated blocking voltage (600 V for the BT137-600E, 650 V for the BT151-650R) or the behavior at high current. A part that looks good at low voltage but turns on by itself at mains voltage is not caught by this test. If doubt remains, replacing the part is safer than testing at mains voltage.

Example calculation: why the resistor and lamp have these values

Gate resistor. When the button is pressed, the gate current is the difference between the supply voltage and the gate voltage divided by the resistance. In the worst case for triggering, VGT is 1.5 V:

IG = (12 V − 1.5 V) / 330 Ω ≈ 32 mA

In the two quadrants the test circuit uses, the trigger limit of the BT137-600E is 10 mA; 32 mA is above this limit, above the 25 mA of the hardest-to-trigger quadrant and above the BT151’s 15 mA limit. A good part triggers at this current. The power dissipated in the resistor does not exceed 12 V × 12 V / 330 Ω ≈ 0.44 W even if the full 12 V is across it; this is why a 0.5 W resistor is chosen. Since the button is pressed only briefly, the resistor has no time to heat up.

If you are going to test a different triac or thyristor, recalculate the resistor according to the maximum trigger current in that part’s datasheet: R ≤ (12 V − 1.5 V) / IGT.

Lamp. When lit, a 12 V 5 W lamp draws approximately 5 W / 12 V ≈ 0.42 A. This current is more than ten times the highest latching current in the table (40 mA). If you put a 20 mA LED and a series resistor in the same circuit instead of the lamp, the current could stay below the latching and holding current limits, and a good triac could turn off when the button is released. This is where the incandescent lamp requirement comes from.

Bar chart comparing the maximum trigger, holding and latching current limits for the BT137-600E with the 32 mA gate current and 420 mA lamp current in the test circuit
The gate current is above the trigger limit, and the lamp current is above the holding and latching limits (BT137-600E). The horizontal axis is logarithmic.

Heating. The on-state voltage of the BT137-600E is at most 1.65 V at 10 A; at 0.42 A it is lower. Even calculating with the upper limit, the dissipated power is 1.65 V × 0.42 A ≈ 0.7 W. Since the package’s junction-to-ambient thermal resistance without a heatsink is typically 60 K/W, the temperature rise is about 42 °C and the junction stays well below its 125 °C limit. No heatsink is needed for the test.

If the triac is good but the load does not work: checking the MOC3021

On microcontroller boards, the triac is usually triggered by an optocoupler with a triac output. The MOC3021 is one of the best known: pin 1 is the LED anode and pin 2 the cathode; the output is taken from pins 4 and 6, pin 3 is not connected, and no connection is made to pin 5.

According to the datasheet, triggering of the MOC3021 output is guaranteed at an LED current of 15 mA (the typical value is 8 mA), and the continuous LED current must not exceed 60 mA. The LED voltage at 10 mA is typically 1.15 V and at most 1.5 V. For an MOC3021 driven from a 5 V output, the series resistor is found as follows:

R ≤ (5 V − 1.5 V) / 15 mA ≈ 233 Ω

220 Ω is very close to this limit: in the worst case the current is (5 − 1.5) / 220 ≈ 15.9 mA, and resistor tolerance or a slight drop in the output voltage uses up the margin. With 180 Ω the worst-case current rises to (5 − 1.5) / 180 ≈ 19.4 mA and stays well below the 60 mA limit. If you see a value greater than 233 Ω in place of this resistor on the board, or if the driver output drops below 5 V, the triac may not trigger even though it is good. You can measure the LED side of the optocoupler across pins 1 and 2 with the multimeter’s diode mode: there should be a reading in one direction only. We cover LED current and resistor selection in detail in the article on optocoupler resistor calculation.

Common mistakes

  • Measuring on the board. Parallel components change the reading; do not draw conclusions without removing the triac.
  • Using an LED instead of a lamp. The current may stay below the latching limit, and a good part looks faulty.
  • Connecting the gate without a resistor. If the gate is connected directly to 12 V, nothing limits the current and the gate can be damaged.
  • Pressing the button in reverse polarity on a thyristor. This applies more than 5 V to the gate in the reverse direction.
  • Assuming the pin order from memory. Another part in the same package may have a different pinout; check the datasheet.
  • Replacing only the triac. If the triac has shorted, look for the cause as well: the load itself, the snubber circuit and the driver optocoupler should be checked.

Frequently asked questions

Can a triac be tested with a multimeter?

Partly. A multimeter shows a short between MT1 and MT2 and a broken gate connection. Its test current is often not enough to show that the triac triggers and stays on; for that, the 12 V lamp test circuit is used.

How many ohms should a good triac read between MT1 and MT2?

A good triac reads open circuit (OL) between MT1 and MT2 in both directions. A value close to zero means a short, and the part should be replaced.

How can you tell a triac has failed?

With a shorted triac, the load never switches off: the lamp stays lit and the motor or heater runs continuously. With a triac that does not trigger, the load never works. In the second case the fault may not be in the triac; the driver optocoupler and the gate resistor should also be checked.

Are triacs and thyristors tested with the same circuit?

Yes, the same lamp circuit is used for both. A triac should trigger in both polarities of the supply. A thyristor triggers only when the anode is positive, and the lamp should never light in reverse polarity.

Does the triac heat up during the test, and is a heatsink needed?

No. With a 5 W lamp the power dissipated in the triac is below 1 W, and the TO-220 package handles this power without a heatsink.

Conclusion

When testing a triac, the multimeter does the first screening and the lamp test gives the verdict. A part that shows a short between MT1 and MT2 is faulty. Test a part that passes the multimeter check with a 12 V, 5 W lamp and a 330 Ω resistor: a triac that lights when pressed, stays lit when released and turns off when the supply is cut, in both polarities, is doing its job. We describe a similar method for MOSFETs in the article How to test a MOSFET.

If a replacement is needed, verify in the datasheet that the voltage, current and trigger current ratings of the new part meet those of the old one. The parts mentioned in this article and similar ones are listed in the Triacs, SCR Thyristors and Triac and SCR Output Optocouplers categories.