OKEN SEIKO P05C05 MİNİ HAVA POMPASI, 12V DC
P05C05 MİNİ HAVA POMPASI, 12V DC
- Manufacturer
- OKEN SEIKO
- Manufacturer Part Number
- Entegreci Part Number
P05C05 MİNİ HAVA POMPASI, 12V DC
P05C05 MİNİ HAVA POMPASI, 12V DC
1. Model: P05C-0005-00
2. Dimensions: As per drawing
3. Voltage & temperature
Rated voltage: 6.0VDC
Operating voltage: 4.5-7.0VDC
Operating temp. : 5℃ to 60℃ with 30% to 80%RH
Storage temp. : -20℃ to +60℃ with 10% to 95%RH
4. Basic performance (against 500cc at 6.0 DVC)
Pressurizing time: Max 10 seconds from 0 to 300mmHg
Current draw: Max 450mA during above pressurization
Leak rate: Max 5mmHg/min at about 300mmHg
Noise level: Max 60dB(A) at 30cm distance from 0 to 200mmHg
Dead head pressure: Min 400mmHg
Re-start voltage: Min 4.5VDC to re-start at 200mmHg up to 300mmHg
5. Durability tests
Performance deterioration must be within 30% (leak may be 18mmHg/min) after each of the following tests. Perfor- mance is measured two hours after returned to room temperature (20℃ to 27℃) from the following temperature involved tests.
Low temperature: Leave the pump in -20℃ atmosphere for 72 hours and return to room temperature.
High temperature: Leave the pump in +60℃ atmosphere for 72 hours and return to room temperature.
High temp. & humidity: Leave the pump in +60℃ & 95%RH for 72 hours and return to room temperature.
Temp. & humidity cycle: (-20℃ for two hours -- +25℃ for an hour -- +60℃ & 85%RH for two hours -- +25℃ for an hour) X 12 cycle and return to room temp.
Standard cycle life: 100,000 cycles of pressurizing test from 0 to 300mmHg. One cycle consists of pressurization, pressure release and several seconds rest time.
6. Recommended installation & examples
Wrap with a piece of soft polyurethane and fix it inside the device used. If a metal binder is used, bind around the motor.
Most preferably horizontal. If vertical, motor side down.
7. Caution
Do not block the air intake port. Minimum opening must be 1.0mm. If a filter is used, avoid close mesh for possible pump damage.
Soldering should be less than 3 seconds at or below 300℃.
Do not press the terminals into the motor.
Positive power to positive mark for wiring.
Solvent may damage plastic parts. Oil & fat, some types of chemicals or plasticizer possibly contained in rubber or silicone tubes may also damage plastic parts.
Pressure range & time used affect on pump life. Avoid much higher or lower pressure than normal range and restless use.
Avoid long period of "shelf time" to keep the best perfor- mance.
8. Packaging
One carton contains 250pcs. Pump model, lot number(s) and quantity are shown on a side face of each carton.
Packaged carton is tested for damage free by dropping at 1m height. Once against a corner, twice against edges and three times against faces.
9. Possible modification
If any change, addition or elimination is necessary, OKEN shall ask for approval before implementation of such modification.








Your Cookie Preferences
We use cookies that are necessary for our website to work. With your explicit consent, we also use additional cookies to measure how you use the site (analytics) and to show you relevant ads (marketing). No cookies are used in categories you do not allow; your visit is measured only with signals that contain no cookies or advertising IDs. You can change your choice at any time with the "Cookie Preferences" link. Cookie Policy · KVKK Privacy Notice
Cookie Preferences
We use cookies that are necessary for our website to work. With your explicit consent, we also use additional cookies to measure how you use the site (analytics) and to show you relevant ads (marketing). No cookies are used in categories you do not allow; your visit is measured only with signals that contain no cookies or advertising IDs. You can change your choice at any time with the "Cookie Preferences" link. Cookie Policy · KVKK Privacy Notice
Cookies needed for the site to work, such as cart, session, security and your selected currency. They cannot be turned off.
Measure visits and site usage with Google Analytics and Matomo, which runs on our own server. Google Analytics data may be processed abroad by Google. If you are logged in, your visits and actions on the site are linked to your member number on our own server. If you do not consent, no analytics cookie is used: your visit is counted without cookies on our own server, and Google Analytics receives only cookieless signals (page address, browser information, your consent status and your actions on the site, such as the products you view and your search terms); Google uses them for aggregate estimates (modeling).
Measure the effectiveness of Google Ads and show you ads that match your interests (remarketing). When you place an order, your e-mail address, phone number and full name are sent to Google in hashed (irreversible digest) form for enhanced conversion measurement; if you are signed in to your Google account, your visits may be linked to your account for cross-device measurement (Google signals). After an order, your e-mail address is also sent to Google for the Google Customer Reviews survey invitation. This data may be processed abroad by Google. If you do not consent, no advertising cookie is used, and your ad click ID, e-mail address, phone number and name are not sent. Google Ads receives only cookieless signals (page address, browser information, your consent status and, when you place an order, the order number, amount and currency); Google uses them for aggregate estimates (modeling).